Product specifications
Page 104 of 146 198-1600-00 Rev F
A.7.5.1 Module Calibration Menu
----------------------- Operate Mode : Amp Gain -------------------
----------------------- Standby Mode : Amp Setting ----------------
.
.
.
Enter the Module calibration menu from the calibrate configuration menu.
This menu is used to calibrate the current and voltage meters and the module
output.
Module Calibration
Menu Page 2
Module
Calibration Menu
(Pg 1 of 2)
.
Select YES to reset all
module calibration
settings to default
values.
The CL01 (module A) and CL05 (module B) menus
show the amp reading offset value. When this menu
is viewed in operate mode the offset value is
automatically computed to achieve a zero reading on
the amp meter when the output is zero.
.
The CL02 (module A) and CL06 (module B) menus
show the volt reading offset value. When this menu
is viewed in operate mode the offset value is
automatically computed to achieve a zero reading on
the volt meter when the output is zero.
.
The CL03 (module A) and CL07 (module B) menus
show the current reading gain value. When this
menu is viewed in standby mode (as shown to the
left) the current setting in amps that will be used for
calibration is shown. The output current can be
adjusted to an appropriate level for calibration.
.
The CL03 (module A) and CL07 (module B) menus
show the current reading gain value. When this
menu is viewed in operate mode (as shown to the
left) the gain value is shown. The gain value is
adjusted to increase or decrease the module output to
match the output current set in CL03/CL07 standby
mode.
CAUTION: Each 18kW output module must be calibrated individually.
There are two module calibration menus, one for module A and one for
module B.