Product specifications
Diamond 10kW Manual Dynatronix, Inc.
198-1603-03 Rev 01 Page 39 of 150
5) From the “Unit Start System Menu” rotate the current encoder until the display shows
“Strt” “End”. Then press the voltage encoder switch to exit the “Unit Start System
Menu” and return to the “System Configuration Menu”.
6) From the “System Configuration Menu” rotate the current encoder until the display
shows “SyS” “End”. Then press the voltage encoder switch to exit the “System
Configuration Menu” and return to the “Unit Configuration Menu”.
7) If any settings were changed in the “System Configuration Menu” you will be prompted
to store the changes. Select “yES” to accept the changes or “no” to cancel the
changes.
6.3.6. Remote Operate/Standby Control (Digital Input)
A digital input can be used to remotely control the operate/standby state. The remote operate
control digital input configurations are described in the table below. The “on 1” and “on 2”
configurations are typically used for a momentary switch contact, such as a push button switch,
although they could also be used with a relay or other switch device controlled by a PLC or other
device.
Digital Input Operate Control Configuration:
“d.in OPEr CtL” = “OFF”
The operate control digital input is disabled.
“d.in OPEr CtL” = “on”
The power supply operates when the operate control
digital input contacts are closed. Opening the
operate control contacts while the unit is operating
will put the unit into standby mode. If the contacts
are opened while a timed cycle (RTC or ATC) is
running the cycle is paused. If the contacts are
closed while a timed cycle is paused the cycle will
resume. Opening the contacts while the end of cycle
state is active (as indicated by “EOC” on the display)
will clear the end of cycle state. Note that the
operate state can be changed by the front panel
operate switch or the host port at any time (see 6.3.7
Front Panel Button Lock Outs to disable the front
panel operate switch).
“d.in OPEr CtL” = “on 1”
The operate state is toggled each time the operate
input contacts are closed. After a timed cycle (RTC
or ATC) completes the end of cycle state is cleared
and a new cycle is started with one closure of the
operate input contacts. If the contacts are
momentarily closed while a timed cycle is running
the cycle is paused. If the contacts are momentarily
closed (less than one second) while a timed cycle is
paused the cycle will resume. If the contacts are
closed for one second or more while a timed cycle is
paused the cycle is terminated, the next contact
closure will start a new cycle. Note that the operate
state can be changed by the front panel operate
switch or the host port at any time (see 6.3.7 Front
Panel Button Lock Outs to disable the front panel