Product specifications
Page 132 of 150 198-1603-03 Rev 01
B.1.17 Error Status Command “m”:
@AA.a
Sync character (@) and unit address, AA = Unit ID (0 to 99; 0 is a global ID), a (n/a,
set to zero)
m0
Command character and Type – 0=read, 1=set(n/a), 2=activate(n/a), 3=ack, 4=nak
#5,
Number of fields character and number of fields after the comma, excluding CRC
(variable)
1,
Error number (0 to 65535)
Bits 15-12 = Alarm source (definition is alarm dependent)
Bits 11-0 = Error Code (0 to 4095)
err
4187,
Error number (0 to 65535)
Bits 15-12 = Alarm source (definition is alarm dependent)
Bits 11-0 = Error Code (0 to 4095)
err
4185,
Error number (0 to 65535)
Bits 15-12 = Alarm source (definition is alarm dependent)
Bits 11-0 = Error Code (0 to 4095)
err
8281,
Error number (0 to 65535)
Bits 15-12 = Alarm source (definition is alarm dependent)
Bits 11-0 = Error Code (0 to 4095)
err
8283,
Error number (0 to 65535)
Bits 15-12 = Alarm source (definition is alarm dependent)
Bits 11-0 = Error Code (0 to 4095)
err
CRC
CRC value in ascii decimal
crlf
Carriage return and Line feed (0x0D 0x0A)
Examples of Alarm Status Command:
read alarm status command from unit 1.
@01.0m0#0,54321
ACK alarm status command with default text delimiters.
@01.0m3#3,4187err,4185err,8281err,54321
ACK alarm status command with comma delimiters.
@01.0m3#4, 4187,4185,8281,8283,54321
ACK alarm status with no alarms set
@01.0m3#0,54321