Product specifications
Diamond 10kW Manual Dynatronix, Inc.
198-1603-03 Rev 01 Page 121 of 150
B.1.12 Setup Command “s”:
@AA.a
Sync character (@) and unit address, AA = Unit ID (0 to 99; 0 is a
global ID), a = Channel ID ( 0 to NUM_CHANNELS; 0 is a global
channel)
s0
Command character and Type – 0=read, 1=set, 2=activate (n/a),
3=ack, 4=nak
#21,
Number of fields character and number of fields after the comma,
excluding CRC.
100.0,
Forward Current Setting – amps (not used when the output waveform
type is set to 2 (custom))
fi
12.25,
Forward Voltage settting – volts (not used when the output waveform
type is set to 2 (custom))
fv
0,
Current Tolerance - Percent of Setting (0 to 100, 0 = disable tolerance
checks)
it
0,
Voltage Tolerance – Percent of Setting (0 to 100, 0 = disable tolerance
checks)
vt
0,
XTC Control (0 = manual, 1 = RTC, 2 = ATC)
xc
1,
XTC Units (0=reserved, 1=ATC Amp Min, 2=ATC Amp Hr,
3=reserved, 4=RTC Min, 5=RTC Hr)
xn
0,
XTC Resolution (0=xxxx, 1=xxx.x, 2=xx.xx, 3=x.xxx)
xr
0,
XTC Preset (0 to 99999999, 0 to 9999999.9, 0 to 999999.99, or 0 to
99999.999, units and resolution are dependent on the xtc units and xtc
resolution specified in this command)
xs
0,
Current Ramp Preset (0 – 300.0 sec)
Irs
0,
Voltage Ramp Preset (0 – 300.0 sec)
vrs
0,
Pulse On Time (0 – 6.553 sec, 0 = DC) (only used when the output
waveform type is set to 1 (pulse))
pon
0,
Pulse Off Time (0 – 6.553 sec, 0 = DC) (only used when the output
waveform type is set to 1 (pulse mode))
poff
0,
Active Waveform Index (1 to 10) (only used when the output waveform
type is set to 2 (custom))
wv
0,
Home Link (1 to 40 = start link for custom wave form operation) (only
used when the output waveform type is set to 2 (custom))
hlnk
0,
Output Waveform Type (0 = DC, 1 = Standard Pulse, 2 = Custom)
wf
100.0,
Reverse Current Setting – amps – positive value (not used when the
output waveform type is set to 2 (custom))
ri
12.25,
Reverse Voltage settting – volts – positive value (not used when the
output waveform type is set to 2 (custom))
rv
0,
Reverse Pulse On Time (0 – 6.553 sec, 0 = DC) (only used when the
output waveform type is set to 1 (pulse))
rpon
0,
Reverse Pulse Off Time (0 – 6.553 sec, 0 = DC) (only used when the
output waveform type is set to 1 (pulse mode))
rpoff
0,
Forward Reading type (0 = Period Average, 1 = Real Time)
frd