Operating instructions
Swim Spa Operator’s Guide
An Internal hardware error has been detected in in.xe.
  • Restart the swim spa pack and start and stop all 
 pumps and blower.
  • If error reappears, replace in.xe swim spa pack.
Water temperature at the heater has reached 119˚F.
DO NOT ENTER SWIM SPA WATER!!!
  • Restart the swim spa pack.
  • If error persists, measure the temperature with a digital 
 thermometer and compare. Its reading with temp. on the 
 display. Make sure the temp. reading is lower than 119˚F.
  • If problem persists, replace pack.
Temperature inside the swim spa skirt is too high, causing the internal 
temperature in the in.xe to increase above normal limits.
  • Remove swim spa skirt and let system cool down, until the 
 error clears.
The system did not detect any water ow while the main pump was running.
  • Make sure valves are open and that water level is 
 high enough.
  • Check and remove anything obstructing the lter.
  • Make sure there are no air locks or that no object 
 obstructs the passage of the water in the heater channel. 
 Pumps may make strange noises. Follow air lock 
 procedure to clear them.
The Prr error message indicates a problem with regulation probe. The system is 
constantly verifying if temperature probe reading is within normal limits.
  • Verify if regulation probe located above the heater is 
 properly connected.
  • Replace in.xe heater is problem persists.
Water temperature in the swim spa has reached 108˚F.
DO NOT ENTER SWIM SPA WATER!!!
  • Measure the temperature with a digital thermometer 
 and compare its reading with temp on the display. If temp 
 reading is different, replace heater.
  • Remove swim spa cover and let swim spa cool down.
  • Add cold water and lower lter cycles.
  • If problem persists replace pack.
Applies to both 
XE / S-CLASS
GENERAL XE PACK DISPLAY DIAGNOSTIC MESSAGE