Operating instructions
Swim Spa Operator’s Guide
01 - Not Used 
02 - Not Used 
03 - 2 Pump 
04 - 2 Pump, Circ 
05 - 2 Pump, Blower 
06 - 2 Pump, Circ & Blower 
07 - 3 Pump 
08 - 3 Pump, Circ 
09 - 3 Pump, Blower 
10 - 3 Pump, Circ & Blower 
11 - 3 Pump, Circ, TV & Speaker lifts 
12 - Not used 
13 - 3 Pump, Blower & Speaker Lift 
14 - 3 Pump, Circ & Speaker Lift 
 (XM) CONFIGURATION
PROGRAMMING THE XM FOR DIFFERENT CONFIGURATIONS
Check water level, make sure all valves are open before switching on power. 
Press and hold the select button for 5 sec. Or until “ll” ashes once. 
Press the change button until the desired conguration number appears 
(See chart below) press select to save changes. 
The LED display will then ash “B2”. This is a current limit setting. 
The most common setting is “32”. Press the change button until desired setting is displayed 
(see current chart below.) Once more press select to save changes. 
The pack will begin a test of all devices and measure the current 
of each device. This information will be used by the pack to check 
for problems and to limit the number of devices used at the same time.
This test will last about one minute depending on number of devices. 
Once complete, the swim spa may be used as normal. 
Programming the XM for Different configurations 
01
02
03
04
05
06
07
08
09
10
11
12
13
14
- Not Used
- Not Used
- 2 Pump
- 2 Pump, Circ
- 2 Pump, Blower
- 2 Pump, Circ & Blower
- 3 Pump
- 3 Pump, Circ
- 3 Pump, Blower
- 3 Pump, Circ & Blower
- 3 Pump, Circ, TV & Speaker lifts
- Not used
- 3 Pump, Blower & Speaker Lift
- 3 Pump, Circ & Speaker Lift
88
Ok
+
Select Change
Check Water Level, make sure all Valves are open before switching ON power.
Press and hold the Select Button for 5 sec. or until “
LL” flashes once.
Press the Change button until the desired configuration number appears
(See chart below) press Select to save changes.
  The LED display will then Flash “ ” this is a current limit setting.
most common setting is “
32”. press the Change button until desired
setting is displayed (See current chart below.) once more press Select
to save changes.
  The Pack will begin a Test of all devices and measure the current
of each device. (this information will be used by the pack to check 
for problems and to Limit the number of devices used at the same time.)
This Test will last about one min. depending on number of devices. 
Once complete the Spa may be used as normal.
Located on the XM.CE pack
BR = 32 1 X 32 Amp GFCI Breaker
BR = 16 2 X 16 AMP GFCI Breaker
BR = 16 3 X 16 AMP GFCI Breaker
settting
Breaker installed in 
power disconnect box
B2
B2
Located on the XM pack 
BR = 32 1 X 32 Amp GFCI Breaker 
BR = 16 2 X 16 AMP GFCI Breaker 
BR = 16 3 X 16 AMP GFCI 
Breaker installed in 
power disconnect box 
Breaker
settting 
BR = 48 for 3 Pump
BR = 40 for 2 Pump 
BR = 24 for 1 Pump
Breaker installed in 
power disconnect box 
Breaker
settting 
Breaker Setting for CE Model
Breaker Setting for ETL Model
20