Install Manual

Page 12 of 18 D00001685 - D52M SoC ANT Module Draft Data Sheet rev 0.4
dynastream.com thisisant.com
D52M M8 Pin
nRF52832
Pin Name
Description
-
P027
General Purpose I/O
P206
P025
General Purpose I/O
Table 2: D52 Module Series Pin-Out
2.3 Preloaded Software
D52 modules are preloaded with the S212 ANT SoftDevice and the ANT Network Processor (NP) application as illustrated
below. Depending on the module revision, the preloaded code may vary. Please refer to Appendix B D52 Module Pre-
Loaded Software Versions for further details. Licensing terms for the preloaded software are described in the Module
Distribution Agreement, which is referenced in Section 4 Licensing & Conditions of Use.
S212 SoftDevice Refer to the S212 nRF52832 SoftDevice Specification.
ANT Network Processor Application Refer to Appendix A Using the ANT Network Processor Configuration
Figure 5: Memory Map of the Preloaded Software
2.4 D52 Module Programming
The D52 ANT SoC module series supports programming by standard Serial Wire Debug (SWD) interface. The two software
components (the SoftDevice and the application code) must be version compatible to operate properly. To ensure proper
operation after reprogramming, it is recommended that the module undergoes a full erasure (e.g. using the erase-all option
in nrfjprog.exe/nRFgo Studio) and all desired software components be explicitly programmed onto the module.
2.4.1
Programming via SWD interface
The D52 ANT SoC Module series supports the Serial Wire Debug (SWD) interface, SWDCLK and SWDIO (refer to Table 2:
D52 Module Series Pin-Out). Programming and debugging of the module only require commonly available tools, such as the
Keil software development environment and the Segger J-Link programmer.
Please refer to “ANT SoC Module Starter Kit User Manual” from Dynastream Innovations for reference software setup and