User's Manual
ANT C7 RF Transceiver Module Page 15 of 20
thisisant.com
3.5 APPLICATION SPECIFIC POWER USAGE
StateSpecificAverageCurrent
The table below lists the average current consumed while ANT is in specific states where a channel is not actively
transmitting or receiving message.
Measured with T
A
= 25°C and V
CC
= 3 V
Symbol Description Value Units
Idle
No active channels and no serial communication 0.91 µA
Suspend
SUSPEND activated in asynchronous serial mode 0.91 µA
Search
Active search on open channel 3.8 mA
The table below lists the average current
per message
as a function of the serial interface and message type. The
message types are:
AverageCurrentperMessage
All current values in µA. Measured with T
A
= 25°C and V
CC
= 3 V. Output power set at 0dBm
Average
Current Per
Message
Transmit
Broadcast
(1)
Receive
Broadcast
(2)
Transmit
Acknowledged
(3)
Receive
Acknowledged
(4)
Transmit-only
Broadcast
(5)
I
Sync_Byte
49 31 70 42 27
I
Sync_Bit
130 94 146 107 127
I
Async_57600
55 34 73 44 37
I
Async_50000
57 38 81 51 39
I
Async_38400
59 41 84 54 44
I
Async_19200
75 55 95 64 66
I
Async_9600
116 84 134 97 107
I
Async_4800
119 141 222 149 189
(1)Transmit Broadcast – Broadcast message transmitted over bi-directional master channel
(2)Receive Broadcast – Broadcast message received by slave channel
(3)Transmit Acknowledged – Acknowledged message transmitted over bi-directional master channel
(4)Receive Acknowledged – Acknowledged message received by slave channel
(5)Transmit-only Broadcast – Broadcast message transmitted by tx-only master channel