User's Manual

Page 14 of 20 ANT C7 RF Transceiver Module
thisisant.com
ReceiveSection
1 Mbps, GFSK, 160-kHz deviation. Measured T
A
= 25°C, V
CC
= 3 V, and f
C
= 2440 MHz, unless otherwise noted.
PARAMETER TEST CONDITIONS Min Typ Max Unit
Receiver sensitivity
0.1% PER -86 dBm
Saturation
10 dBm
Co-channel rejection
-9 dB
Adjacent-channel rejection
± 2 MHz 23 dB
Alternate-channel rejection
± 4 MHz 39 dB
Frequency error tolerance
(1)
Including both initial tolerance and drift -150 150 kHz
Symbol rate error tolerance
(2)
-50 +50 ppm
Spurious emission. Only
largest spurious emission
stated within each band.
Conducted measurement with a 50 Ω single-ended
load.
-70 dBm
(1) Difference between center frequency of the received RF signal and local oscillator frequency.
(2) Difference between incoming symbol rate and the internally generated symbol rate
TransmitSection
Measured with T
A
= 25°C, V
CC
= 3 V, and F
C
= 2440 MHz unless otherwise noted.
PARAMETER TEST CONDITIONS Min Typ Max Unit
Output power,
maximum setting
Conducted measurement delivered to a single-ended 50 Ω
load through a balun using maximum recommended output
power setting.
4 dBm
Output power,
minimum setting
Conducted measurement delivered to a single-ended 50 Ω
load through a balun using minimum recommended output
power setting.
-21 dBm
Programmable
output power range
Delivered to a single-ended 50 Ω load through a balun.
25 dB
Spurious emissions,
conducted
Conducted measurement with a 50-Ω single-ended load.
Complies with EN 300 328, EN 300 440 class 2, FCC CFR47,
Part 15 and ARIB STD-T-66.
(1)
-45 DBm
Average EIRP,
Maximum setting
Radiated measurement with the module mated with ANTUIF
(1)
board in an anechoic chamber at 2403 MHz.
-3.5 dBm
(1) ANT USB Interface board is provided in the ANTC7EK1 development kit