1 ANT AP2 Module
The ANT AP2 module is a drop-in module based on the reference design of nRF24AP2, a new generation of
ANT system on chip family from Nordic Semiconductor. An F antenna is integrated on the small-sized
20mm by 20mm board. The module has been certified to comply with radio regulation or standards
covering global markets include North America, Europe, Japan and Australia. The integrated module eases
the burden for application and system developers from extensive RF and antenna design, and regulatory
compliance testing, allowing quicker time to market. Able to support 8 ANT channels, the module is ideal
to build control or hub nodes of a wireless sensor network.
AP2 modules are currently available in the following varieties.
Module
A
NT chip
Used
Description
ANTAP281M4IB nRF24AP2-8ch
Surface mountable, 8 ANT channels, 20x20mm, industrial
temperature range
ANTAP281M5IB nRF24AP2-8ch
With Molex connector, 8 ANT channels, 20x20mm, industrial
temperature range
1.1 Interface
The module may be connected to the user’s host controller using the 17 pin-out assignment (surface
mount) style or the 20-pin Molex header connection style provided below:
Surface
Mount Pin
Molex
Header Pin
Pin Name Async Mode Sync Mode Description
1 6 TEST
TEST (Tie to
GND)
TEST (Tie
to GND)
Tie to Ground
2 10 RST RST RST Reset the device
3 1 V
CC
V
CC
V
CC
Power supply source
4 19 GND GND GND Power supply ground
5 8 NC NC NC No connection
6 17
SUSPEND
/SRDY
SUSPEND
SRDY
Async -> Suspend control
Sync -> Serial port ready
7 15
SLEEP/ MRDY
SLEEP
MRDY
Async -> Sleep mode enable
Sync -> Message ready indication
8 13 NC NC NC No connection
9 11 PORTSEL
PORTSEL
(Tie to GND)
PORTSEL
(Tie to V
CC
)
Asynchronous or synchronous port
select
10 7
BR2/SCLK
BR2 SCLK
Async -> Baud rate selection
Sync -> Clock output signal
11 4 TXD0/SOUT TXD0 SOUT
Async -> transmit data signal
Sync -> Data output
12
3
RXD0/SIN RXD0 SIN
Async -> Receive data signal
Sync -> Data input
13 5 BR1/SFLOW BR1 SFLOW
Async -> Baud rate selection
Sync -> Bit or byte flow control
select
14 9 BR3 BR3 Tie to GND
Async -> Baud rate selection
Sync - > Not used, tie to ground
15 14 RESERVERD2 Tie to GND Tie to GND Reserved Pin, Tie to ground
16 12 RESERVERD1 Tie to GND Tie to GND Reserved Pin, Tie to ground
17 2 RTS/SEN RTS SEN
Async -> Request to send
Sync -> Serial enable signal
16,18,20 NC NC NC No connection