Instruction Manual

Rev. 5/09 -3.6- TFXP
Transducer
Mounting
Method
XDCR MNT -- Transducer Mounting Method (Choice)
1. V
2. W
3. Z
Selects the mounting orientation for the transducers. The selection
of an appropriate mounting orientation is based on pipe and liquid
characteristics. See Part 2 – Transducer & RTD Installation in this
manual.
PIPE OD -- Pipe Outside Diameter Entry (Value)
1. ENGLSH (Inches)
2. METRIC (Millimeters)
Enter the pipe outside diameter in inches if Englsh was selected as
Units; in millimeters if Metric was selected.
PIPE WT -- Pipe Wall Thickness Entry (Value)
1. ENGLSH (Inches)
2. METRIC (Millimeters)
Enter the pipe wall thickness in inches if Englsh was selected as
Units; in millimeters if Metric was selected.
PIPE MAT -- Pipe Material Selection (Choice)
1. Acrylic (ACRYLIC)
2. Aluminum (ALUMINUM)
3. Brass [Naval] (BRASS)
4. Carbon Steel (CARB ST)
5. Cast Iron (CAST IRN)
6. Copper (COPPER)
7. Ductile Iron (DCTL IRN)
8. Fiberglass-Epoxy (FBRGLASS)
9. Glass Pyrex (PYREX)
10. Nylon (NYLON)
11. HD Polyethylene (HDPE)
12. LD Polyethylene (LDPE)
13. Polypropylene (POLYPRO)
14. PVC CPVC (PVC/CPVC)
15. PVDF (PVDF)
Pipe
Diameter
Pipe
Material
Pipe Wall
Thickness
PART 3 - KEYPAD CONFIGURATION