Instruction Manual

21
MENU key, press key to step through setup. Press ENTER to
edit a value. Press ENTER to save a value.
RATE UNIT GPM M3/H BPD LPM
TOTAL UNIT GAL M3 BBL LIT
FLOW DIR POS NEG
FULL FLOW 0-9999 Rate Unit
FLOW C-OFF 0-999.9 Rate Unit
OUTPUT NONE 4-20MA PULSE
RESPONSE FAST MED SLO
Press MENU to exit.
RATE UNT -- Engineering Units for Flow Rate
GPM—Gallons per minute
LPM—Liters per minute
BPD—Barrels per days (42 U.S. gallons)
M3/H—Cubic meters per hour
1. To change flow rate units, press the MENU key.
2. Press the
key to display RATE UNT on bottom display.
Press ENTER key.
3. Press the
key to select new rate unit (four selections
located in the upper right-hand corner of the display.
4. Press the ENTER key.
5. Press the MENU key to exit.
TOTL UNT -- Engineering Units for Flow Totalizer
GAL - U.S. Gallons
LIT - Metric Liters
BBL - Oil Barrels (42 U.S. Gallons)
M3 - Cubic Meters
1. To change flow totalizer units, press the MENU key.
2. Press the key to display TOTL UNT on bottom display. Press
ENTER key.
3. Press the key to select new totalizer unit.
4. Press the ENTER key.
5. Press the MENU key to exit.