User manual
DynamixUM‐SNBUserManualVer1.0072
4.4.4. UM-SNB/3in1 / UM-SNB/3in1/4w E1+Serial+Ethernet interface model -- E1+Serial Interface mode
Interface
□E1 □Serial □Ethernet
⊠E1+Serial □E1+Ethernet
NTU
Type □STU-R □STU-C-INTCLK □STU-C-EXTCLK
Annex □A □B □F □G
PSD □SYM □ASYM
SNR Margin (-10~21)
SHDSL
Pair Mode □1 Pair □2 pair (For UM-SNB/3in1/4w only)
Channel □PCM31 □PCM31C □PCM30 □PCM30C □Unframed
Slot Number
First Slot
Code □HDB3 □AMI
AIS □Off □On
E1
Build Outs □75 Ohm □120 Ohm
Interface □V.35 □X.21
□Nx64K □T1 mode
Data Rate
Clock □Normal □Inverse
RTS □On □From DTE
CTS □On □Off □From RTS
DSR □On □Off □From DTR
DCD □On □Off □From DSL
Serial
Delay □0mS □1mS □2mS □3mS
When SHDSL.bis using 2-pairs (4-wires), the E1 time slot number and Serial Nx64K data rate number can only use even
number.
When E1 framer is PCM31C and PCM30C and set pass through ON, no fractional function can be use.