User manual

DynamixUMSNBUserManualVer1.00122
The table of SHDSL line rate vs. data rate:
Data Rate (kbps)
SHDSL Line rate
Number of time
slot for E1
Nx64K for Serial
and Ethernet
5696(n=89) Cannot use 89
5632(n=88) Cannot use 88
5568(n=87) Cannot use 87
………….. ………..
………….. ………..
………….. ………..
………….. ………..
2368(n=37) Cannot use 37
2304(n=36) Cannot use 36
2240(n=35) Cannot use 35
2176(n=34) Cannot use 34
2112(n=33) Cannot use 33
2048(n=32) 32(unframed) 32
1984(n=31) 31 31
1920(n=30) 30 30
1856(n=29) 29 29
1792(n=28) 28 28
………….. ………..
………….. ………..
………….. ………..
………….. ………..
384(n=6) 6 6
320(n=5) 5 5
256(n=4) 4 4
192(n=3) 3 3
192(n=3) 2 2
192(n=3) 1 1
Due to SHDSL.bis working line rate starts up from 192kbps(n=3) , all setting on all interfaces with apply 64kbps(n=1) and
128kbps(n=2) are actually using on 192kbps DSL line rate.
The above table is for using as Annex F and G. When using Annex A and B, no N values more than 36.