User manual

17
slot engrossment and same setting of PCM30/31 and CRC. However, Passive Bandwidth Control
function and E1 loop-back test of remote converter cannot be used.
z Compatibility with other V.35 products
Answer: RC903-V35FE1 and RC904-V35FE1 can cooperate with other products that have similar
functions, such as followings:
1. SUBM-FV35, N x 64K V.35 interface module, can be installed in RC800-240B series standalone
PDH fiber-optic multiplexer.
2. RC800-30B-FV35, N x 64K V.35 interface PDH fiber-optic multiplexer, equipped with all the
functions of RC903-V35FE1 and RC800-30B single E1 PDH fiber-optic multiplexer.
ORDERING INFO
RC 903 - V35FE1: Standalone, V.35 to transparent or
fractional E1 interface converter, AC 115V or 230V/DC-48V