User guide
76
4. Configure incoming Ring Cadence to FXO Gateway
Advance
Ring to configure proper Ring Cadence ( Ring ON time and Ring
OFF time ) according to the PABX or PSTN ring Cadence specification.
Without configuring Ring Cadence to FXO gateway properly according to PABX
or PSTN Ring Cadence, FXO may detect Ring signal in a strange behavior and
cause abnormal operation.
seconds OFF. Some PABX or PSTN provides 1 second ON and 3 seconds OFF
second ON and 3 seconds OFF to match incoming Ring signal. See Figure 17.
See Figure 17.
5. Enable Caller ID function at FXO and FXS gateway.
The Caller ID configuration at FXO gateway should be configured to match
PABX extension or local PSTN Caller ID incoming signal in order to carry this
signal to remote FXS gateway to display at FXS analog phone set. Of course,
the remote FXS Gateway also has to enable Caller ID generation function ( see
Figure 21. ) Here are steps to enable FXO Caller ID detection specification and
enable FXS gateway Caller ID generation steps.
FXO gateway is the same as PABX extension or local PSTN switch which
ID mode you need to configure at FXO gateway, please consult to PABX
suppliers or PSTN local switch technician to support you. In global market,
there are several Caller ID modes which are most used such as Bellcore FSK,
ETSI FSK, ETSI DTMF, Danish DTMF, India DTMF, Brazilian DTMF. See Figure
18.
When you connect Dynamix 2540 FXO gateway Lines to local PABX’s extension
or PSTN switch, please go to Dynamix 2540 webpage setting at VOIP
Dynamix 2540 factory default Ring Cadence setting is 2 seconds ON, 4
Ring Cadence. In this case, please configure Dynamix 2540 Ring Cadence to 1
Step 1: Make sure the Caller ID mode you have configured to
Dynamix 2540
Dynamix 2540 FXO Line ports have connected. If you don’t know what Caller