User guide

Dynamix DW-E
69
Auto Send 183: Dynamix DW-E always send Call Progress Indicator
(SIP 183) to VoIP party. It can be used for CAS protocol to enable early
media.
Behind NAT: Does Dynamix DW-E is located behind NAT or not
Public Signal IP: The static mapped IP for SIP signal
Public Signal Port: The static mapped Port for RTP stream
Public RTP IP: The static mapped RTP IP
Public RTP Port: The static mapped RTP starting port
Public RTP Port Interval: The Dynamix DW-E has at least 30 RTP
channels. Each channel needs 3 ports mapping on NAT Server. The
interval is used to calculate the right port for each channel.
Overload Redirect: SIP overload redirect when Dynamix DW-E is not
able for service the call
Redirect Host: Redirect host URI (format: user@sip host, sip host)
Redirect Port: Redirect port number
Send 487 When Recv CANCEL: When receive CANCEL form remote
site, send “487 Request canceled” or not
Caller ID Mode:
o Local: use Dynamix DW-E proxy user id
o Caller: use SIP calling party ANI
Receive Hold music source:
o Auto: Auto determinate to play hold tone based on SIP signaling.
o Local: Play holds tone locally.
On Hold music: Hold tone music file name
SIP UnRegist When Trunk Down: Enable or disable un-register when
all trunks are down. It can be used for load balancing.
SIP Over Load Reason: When all trunk are busy, the reason to send to
caller. Default is 438. When work with WS6500, 438 is required for load
balancing hunting.
Refer Call Use Refer By User: When a call is been transferred, new call
will use REFER-BY ID instead of original caller ID.