User guide
Dynamix DW-E
35
o Info Type: The info type to be validation
-DNIS: Called number
-ANI: Calling number
-IP: In coming IP address
-User: User ID
o Allow To: If it is met the ACL defined
o Disallow To: If it is not met the ACL
defined
• CTB: Call Type Branch
o
PSTN To: Route for PSTN call
o
H.323 To: Route for H.323 call
o
SIP To: Route for SIP call
• Cut Rule: Cut a system variable into different parts
o
Cut From: Cut start digit from (start from 1)
o
Cut To: Cut end digit to
o
Assign To: Store the cut result into
• Disconnect: Disconnect the call