User guide
Dynamix DW-E
34
о Check Parameter: Check parameter type (DNIS, ANI….)
о Digit From: Start digit from
о Digit To: End digit to
о Valid To: If the checked variable is success to validate
о Invalid To: If the checked variable is not success to validate
• CIB: Call Information Branch
o Info Type: Information type selection
- ANI: Calling Number
- DNIS: Called Number
- IP: IP Address or network (e.g. 192.168.0.0)
- PSTN: E1/T1 trunk and channel filter, format: interface id-
trunk id- trunk start- trunk stop
- Prefix: The prefix to be match
0-1-17-31:
0: Interface ID (Always 0)
1: Trunk ID: 1
17: Start from B Channel 17
31: Stop from B Channel 31
o Goto: The component to run next
o Call Info Branch Line: ANI, DNIS, IP or PSTN goto
setting
• CIV: Call Information Validation, the user need setup the ACL for
DNIS and IP TO take effect
• CDV: Collected Digit Validation