T1 E&M FGB Wink
T1 E&M FGB Wink (ANI B4 ADDRESS)
T1 E&M FGD Wink
T1 E&M Immediate
T1 E&M Immediate Start
T1 E&M Wink
T1 E&M Wink Start A-Bit Only FXO
T1 E&M Wink Start A-Bit Only FXS
T1 E&M Wink Start
T1 Ground Start FXO
T1 Ground Start FXS
T1 Loop Start FXO
T1 Loop Start FXS
Dynamix DW-E FAQ
Q1. Forgotten user password to logon Dynamix DW-E.
Answer:
a. Logon by a user has Administrator right to reset the user’s password
b. If there is no any users can logon, use the following user/password for
emergency recovery:
User: Serial no (from license card)
Password: first 8 characters of “License Key” (from license card)
c. Use the LCD control panel to change the user id: admin or root’s
password.
Q2. In H.323 Mode: Cannot hear ring back tone for PSTN caller.
Answer:
Normally the ring back tone is generated by the nearest PABX connected to
DW-E. If a caller from PSTN site cannot hear the ring back tone, please
check:
a. Consult to PABX/PSTN vender to clarify the PABX/PSTN will generate
ring back tone.
b. For Fast Start mode, make sure the far end VoIP end point will have
ring tone generated. For example, a PSTN subscriber calls a VoIP
H.323 Lan-Phone. When it is on Fast Start mode, DW-E will cut
through the voice path after receive Fast Start Ack. Please make sure
the Far End VoIP Endpoint will generate ring back tone over RTP
media path to DW-E.
c. If you really need DW-E to generate PSNT ring back tone, please
do the following setting:
- Turn on “local ring back” from “Interface -> Trunk” for each
trunk required local ring back tine generation.
- Disable Fast Start for H.323 outgoing call (set to disable or
H.323 incoming call only.)
Q3. In H.323 Mode: DW-E cannot keep registering to Gatekeeper after
Gatekeeper restarted.