User manual

Dynamix DW-2/4 FXO SIP Gateway User Manual
Note: be sure to know well the application before you change voice
parameters because this might cause incompatibility.
4.2.18 [tone]
This command is basically for FXO ports.
--------------------------------------------------------------------------------------------
usr/config$ tone
Disconnect tone and remote ring back tone configuration
Usage:
tone [num][freqHi ][freqLo ][freqHiLev][freqLoLev]
[Tone1ON][Tone1OFF][Tone2ON ][Tone2OFF ]]
tone -print Display disconnect tone configuration.
[num] Tone index(1~4:Disconnect tone / 5~8:Remote ring back
tone). Example:
tone -print
tone 1 620 480 8 8 50 50 1023 1023
usr/config$
Parameter Usages:
-print show all tone configuration
[num] tone index. 1~4 is disconnect tone, 5~8 is remote ring back tone.
For FXO ports Gateway must detect disconnect tone to determine
when to disconnect the call, so user must set disconnect tone of
PBX or PSTN network connected to FXO ports. When making a
call from FXO ports, there are 2 ways to detect callee has
already picked up the call, one is to detect reverse signal, the
other is to detect the termination of ring back tone, so user must
set ring back tone of PBX or PSTN network. (If user doesn’t know
about the frequency of disconnect tone or ring back tone, please
refer to [record] command to detect frequency.)
72