User`s manual

Dynamix DW-01Plus/S Gateway User Manual
- 52 -
Low(lev) : Level (volume) of Low frequency
High(lev) : Level (volume) of High frequency
On1 : On cadence of first cycle
Off1 : Off cadence of first cycle
On2 : On cadence of second cycle
Off2 : Off cadence of second cycle
Note:
1. If disconnect tone is single-frequency, user has to conf
igure the same frequency
value of Low frequency and High frequency; the same level of Low frequency
and High frequency
2.
For On/Off cadence, user must set 1023 instead of 0, if there is only one set of
cycle, please as in second set columns