User manual

Dynamix DW-Phone LP-201 VoIP Phone
(A) LCD menu password: User can enter LCD system configuration by key in
this password and default value is lowercase “x.” (Press TRANSFER to switch
lowercase and uppercase, then press 9 twice).
(B) H.235 security: To set RRQ/ARQ authentication token password. If
Dynamix DW - Phone LP-201 VoIP wants to register to a Gatekeeper,
which implement H.235 security token feature, LAN Phone has to set a
RRQ/ARQ authentication token password, which is provided by Gatekeeper
manager. Dynamix DW - Phone LP-201 IP Phonecan’t work normally with this
Gatekeeper unless Token Password is set.
- RTP Port: Assign RTP port number (1024-65535). Dynamix DW - Phone LP-201 IP
VoIP need 2 RTP ports for voice communication, the port number assigned here
is a base, for example, default value is 16384, that means Dynamix DW - Phone
LP-201 IP Phonewill use port 16384 and 16385 for RTP packets.
- Response Timeout: set max waiting time for first response to a new call. After dial
phone number without getting response in max waiting time, user will hear busy
tone. (1-200 seconds)
- Connection Timeout: set max waiting time for call establishment after receiving first
response of a new call (1-20000 seconds).
30