User Manual

Dynamite Vision Ultra AC/DC Charger
www.DynamiteRC.com 7
7. Press the “Mode” button to return to the
charging screen.
8. Press the “Start” button to begin charging.
The Start button can be pressed at any time to
stop or resume charging.
To Set Another Charge Memory
Press the arrow keys and scroll to another
memory selection (0–9) and see instructions
above to set the charger perameters.
NOTICE: Also consider the battery pack’s
series cell count (e.g., 2S, 3S, 4S, etc…) as
the voltage of the pack being charged will
affect the available charge current in order
to not exceed the 50-Watt maximum
output limit of charger (1–5A for 2S pack;
1–4A for 3–4S pack). Using a charge rate
that is not compatible with the above
mentioned battery capacities may result in
damage or malfunction of the charger or
batteries.
Special Notes for
Li-Po/Li-Fe/Li-Ion packs:
A completely discharged Li-Po/Li-Fe/Li-
Ion battery pack can be fully recharged in
approximately 2–3 hours with charge rate at
1C. Do not set the charge rate higher than
the capacity of the battery when charging a
Li-Po/Li-Fe/Li-Ion.
Special Notes for Pb batteries:
Suggested charge rate for Pb charging is 0.3C
(e.g., .3 x 5Ah=1.5A).
WARNING: If at any time during
the charge process the battery pack(s)
become hot or begin to puff unplug the
battery immediately and discontinue the
charge process as batteries can cause fire,
collateral damage and serious injury.