User Manual
12 www.DynamiteRC.com
Dynamite Ultra AC/DC Charger/Cycler
Dynamite Ultra AC/DC Charger/Cycler
www.DynamiteRC.com 13
Li-Ion/Poly Charge Warning Message
ERR Batt
Over Voltage
1. Battery Over Voltage
WARN
Volt Select Err
2. SetWrongBatteryVoltage
ERR Batt
Low Voltage
3. Battery Low Voltage
Li-Ion/Poly Balance Charge Mode
Li-Poly Bal. Chg
4.0A 14.8V(4S)
Message during Li-Ion/Poly Balance
Charging
Li4S 0000:01 0001
Bal 0.10A 15.18V
See the status by turning switch to left/right
(same as Li-Ion/Poly Charge.)
Message after Li-Ion/Poly
Balance Charging
4.16 4.16 4.16
4.16 0.00 0.00
1. Battery Voltage Per Cell
High 4.165V (S2)
Low 4.162V (S3)
2. The above screen shows which battery has
the High/Low voltage
NOTE: The second battery has the high voltage.
The third battery has the low voltage
Unbalanced Volt
3mV
3. Unbalance Voltage
The voltage difference between the high voltage
and low voltage cells in the battery pack.
Li-Ion/Poly Balance Charge
Warning Message
WARN
Volt Select Err
1. SetWrongBatteryVoltage
Balancer
No Connect
2. Balance Leads not Connected
Unbalance Volt
Over 30mV
3. Shows that the unbalanced voltage is above
the 10mV limit at 30mV. The charge will
automatically switch to a 100mA charge rate
until the battery cell voltages are balanced to
less than 10mV. The charger will begin normal
charging after the cells are balanced.
Cell Number 1
Volt Over 4.26V
4. Battery voltage is over 4.26V per cell.
See previous step. The charger will drop to a
low current rate until the cells are balanced
within specications.
Li-Ion/Poly Discharge Mode
Li-Poly Dischg
1.0A 12.0V(4S)
Message during Li-Ion/Poly Discharging
Li4S 0000:01 0001
DIS 1.00A 15.18V
See the status by turning the dial during
discharge.
Select Voltage
12.0V (4S)
1. Selected Discharge Voltage Cutoff
Discharge voltage is pre-set to 3.00V/cell and
the corresponding S count will be displayed
along side the voltage cutoff being selected.
Selecting the correct S count will automatically
set the appropriate voltage cutoff.
Input 13.01V
System Temp 36°C
2. DC Input Voltage/System Temperature
WARNING: Li-Po batteries can cause
serious injury and fire if charged inappropriately.
Always confirm the battery voltage and series
cell count is correct and never charge higher
than a 1C rate. (1C – charger current equals the
battery capacity. Example A: 1000mAh battery’s
charge current limit is 1 amp. Example B:
3300mAh battery’s charge current is 3.3A)