6 www.DynamiteRC.com
Dynamite Ultra AC/DC Charger/Cycler
Dynamite Ultra AC/DC Charger/Cycler
www.DynamiteRC.com 7
Operating Instructions
A. Press the MODE button to change from the
main menu to the setting menu. Rotating
the dial in the main menu lists all options
available for the battery chemistry shown
on the screen. Rotating the dial while in the
settings menu lists menus that allow changes
to the chargers functionality unrelated to the
battery type.
B. Press the START button to change the
selected menu.
C. Press START to conrm the option. Press
STOP to clear settings.
D. Press and hold the START button for 3
seconds to charge/discharge.
User Setup Menu
NOTE: Screen samples are shown in the order in
which they appear when the dial is rotated in a
clockwise direction.
User Setup Mode
Type NiMH Batt
1. Select Battery Type
Press the MODE button until the User Setup
mode appears. Scroll clockwise to view the
following screens. Press the START dial to
change values on each screen while ashing.
Press the START button to accept settings.
Li-Ion/Poly
V-Type 3.7V
2. Select Li-Ion/Poly Voltage
Use this screen to select the Li-Ion/Poly
charge cutoff voltage.
NiMH Sensitivity
D.Peak 3mV/Cell
3. Adjust Ni-MH Charge Sensitivity
The Ni-MH Sensitivity option allows the
adjustment of the Ni-MH negative delta
voltage cutoff/cell.
Nicd Sensitivity
D.Peak 5mV/Cell
4. Adjust Ni-Cd Charge Sensitivity
The Ni-Cd Sensitivity option allows
adjustment of the Ni-Cd negative delta
voltage cutoff/cell.
Batt Temp Cutoff
ON 50°C
5. Adjust Max Charge Temperature and change
Celsius to Fahrenheit
As a safety feature, place temperature
probe securely onto battery pack to allow
temperature override.
Cycle Charge
Delay 1min
6. Adjust Charge/Discharge Delay Time
NiMH/Nicd/Pb
Trickle 100mA
7. Adjust Trickle Charge Current
Safety Timer
ON 720min
8. Adjust Max Charge Time
Capacity Cut Off
ON 9900 mAh
9. Adjust Max Charge Capacity
Key Beep ON
Music 01
10. a) Set Operating Beep Sound (On/Off) or
b) Select Music
Volume Adjust
100%
11. Adjust Volume
Input Volt Low
Cut Off 11.0V
12. Set Detecting Input Low Voltage
Back Light
Brightness 100%
13. Adjust Background Brightness
Load Default
YES/NO ?
14. To reset the charger to Initial Setting
Ni-MH and Ni-Cd Charge Mode
NiMH Charge
4.0A
Message during Ni-MH Charging
WhileintheUserSetupmode,pressthedialto
change to Ni-MH battery charging. Press the dial
again to conrm changes.
NiMH 000 : 01 : 0001
Chg 0.10A 7.62V
See the status by turning switch to left/right.
Press the MODE button to adjust the charge
current. Press the START dial and adjust the
current rate to the appropriate rating.
Press and hold the dial for 3 seconds to activate
charge. The charge status and other settings
can be monitored by rotating the dial during fast
charge.
NiMH Sensitivity
D.Peak 3mV/Cell
1. Ni-MH Charge Sensitivity
To reset to factory recommended sensitivity,
see Load Default and select “Yes.