Cable specifications – curly cable
DX BUS Curly Cable
Tail Length La Coil Length Tail Length Lb Part/Order number
200 mm / 8 inch 300 mm / 1 ft 200 mm / 8 inch GSM63051
500 mm / 1'8" 300 mm / 1 ft 200 mm / 8 inch GSM63052
Parameter Value
Connector Latch Holding Force 40 N min
Cable Strain 100 N max (accidental, non-repetitive)
Spring Force -
extension refers to the coiled section
< 20N @ 2x extension (T > 10°C/50°F)
< 50N @ 2x extension (T > –10°C/14°F)
< 30N @ 3x extension (T > 10°C/50°F)
Minimum Cable Bend Radius
Flexing values for (T > –10°C/14°F)
20 mm / 0.8 inch - fixed installation
30 mm / 1.2 inch - occasional flexing
50 mm / 2 inch - frequent flexing
Operating Temperature
(ambient, fixed installation)
–25°C to +50°C
–13°F to +122°F
Cable Temperature Rating 80°C / 176°F (internal operating temp)
Warnings:
1. Do not extend the coils when the temperature is below 0°C/32°F.
Do not extend the coils farther than 2x compressed length when the
temperature is below 10°C/50°F.
Avoid extension above 3x compressed length at all times. This may
result in permanent stretching of the coils.
2. Make sure that the spring force is not applied to the DX BUS connector.
Fasten a strain relief or cable tie on or near to the coiled section of the
cable.
R
-
B
E
N
D
La ± 20
Ø26 ± 2
300 ± 30 approx. 40 coils
compressed coil length
Lb ± 20
Ø7.5
13 x 16
40