6 The DX BUS cable
Cable specifications – straight cable
DX BUS cable straight
Length Part/Order number
300 mm 1 ft GSM63003
500 mm 1' 8" GSM63005
1.0 m 3' 3" GSM63010
1.5 m 4' 11" GSM63015
2.0 m 6' 7" GSM63020
2.5 m 8' 2" GSM63025
DX BUS cable with Ferrite bead to improve EMC
2.0 m 6' 7" GSM63020F
DX BUS extension cable (male + female plug)
300 mm 1 ft GSM65433
1.0 m 3' 3" GSM63081
Parameter Value
Connector Latch Holding Force 40 N min
Cable Strain 100 N max (accidental, non-repetitive)
Cable Flex Force 10 N max
Minimum Cable Bend Radius
Flexing values for (T > –10°C/14°F)
10 mm / 0.39 inch - fixed installation
25 mm / 1 inch - occasional flexing
50 mm / 2 inch - frequent flexing
Operating Temperature
(ambient, fixed installation)
–25°C to +50°C
–13°F to +122°F
Cable Temperature Rating 80°C / 176°F (internal operating temp)
Warnings:
1. The specified bend/flex radiuses are minimum values and must be
considered as a guideline only. Where frequent flexing is part of the
intended application, the installer must ensure an appropriate
bend/flex radius for the intended and foreseeable environmental
conditions.
2. Extreme cold temperatures considerably reduce cable flexibility.
Appropriate life testing must be carried out to determine/confirm the
expected service life and inspection and maintenance schedule.
35
YY x 100 ± 10
Ø7.0
13 x 16
R
-
B
E
N
D