User's Manual
Page | 20
5.0 STANDARD FUNCTIONS
5.1 PEAK HOLD
The Peak Hold function is turned on by pressing the Peak Hold button on the front of
the TW-3.0.
The Peak Hold function will store the highest value seen on the TW-3.0 until the
function is turned off.
5.2 TARE
The Tare function is turned on by pressing the button on the front of the TW-3.0.
The Tare function will set the display to zero when it is turned on, and then reset back
to raw input when turned off.
The Tare function will take into account any load applied to the load cell when
displaying the Overload warning.
Example:
The load cell has an Overload warning set at 10.00T.
2.00T is applied to the load cell and then the tare button is pressed.
The display can now increase to 8.00T before the Overload warning will trigger.