EXO-SKIN Installation Quick Start Guide 10808 Fallstone Road #350 Houston, TX 77099, USA Tel: 281-564-5100 Fax: 281-564-5200 Toll Free: 800-896-7108 admin@dynamax.com dynamax.
EXO Sensor Installation Power should be off during all steps 1) Prepare the stem by smoothing the thin bark, or removing thick bark with sandpaper if necessary. Small stems may be removed and sanded smooth. Try to minimize the damage to the living tissues of the plant. 2) Wash with soapy water. 3) Measure the stem diameter in mm. You can use an average diameter if the stem is not perfectly round. 4) Spray a thin layer of canola oil around the stem.
8) Note the sensor Ohms resistance value written on the sensor cable. 9) Attach the cable. There is a notch to line up the connectors then there is a “click” when the connector is completely tight. 10) Install the (3) foam bodies with Velcro straps. The cable goes inside the gap of the bottom foam body before the Velcro strap is tightened. 11) Install the white waterproof membrane cloth with a nylon wire – tie or Velcro strap at the top and at the bottom.
10808 Fallstone Rd #350 Houston, TX 77099, USA Tel: 281-564-5100 Fax: 281-564-5200 www.dynamax.