User's Manual
DEVICE DESCRIPTIONS
5-42 PROANNOUNCE System User Handbook 1.1
5.2.11 Factory Presets
When shipped, the selection keys 1 – n are assigned to the corresponding areas 1 – n offering real plug ‘n’ play;
the paging station is ready for operation directly after connection and switching the system power ON.
CAUTION: When operating several paging consoles within one installation, setting every single one
to its individual, exclusive address (1 - 16) is of major importance.
The paging stations provide the following factory pre-set functions and characteristics:
Parameter Setting / Description
Address
OFF
Priority
5 (priority for messages)
Name
Untitled DPC4xxx (Type)
Password
Level 1 not protected
Level 2 password-protected
Default password level 1: 111
Default password level 2: 2222
Pre-gong signal
OFF
Buzzer
ON (acoustic alert signal)
Compressor
OFF
Extension socket EXT
OFF
Options
2
nd
alarm key Not programmed
Key-lock switch Not programmed
PTT-microphone Call in pre-selected areas, priority 5
Key-assignment
Selection keys 1 – n Selecting areas 1 – n (
key 1
à
area 1, key 2
à
area 2, ..)
(not with DPC 4106)
TALK Call in pre-selected areas, priority 5
(DPC 4106: calls in all areas)
TEXT Text message in pre-selected areas; text 1, priority 2
(DPC 4106: text message transmission in all areas)
GONG 4-stroke gong signal in pre-selected areas, priority 8
(DPC 4106: gong signal transmission in all areas)
ALL Selecting collective call
CANCEL Cancel selection / call-pattern
(not with DPC 4106)
ON Switching the system ON / OFF, priority 5
STOP Terminates any locally launched signal (gong, text, alarm)
PROGRAM Assigns a program to pre-selected areas
(not with DPC 4106)
ALARM DIN-alarm in all areas, priority 9
(not with DPC 4106)
Special functions
Not programmed