User`s manual
User’s Manual
61
3.3.18 ALARM SETTING
The Dome Camera provides eight alarm inputs and one alarm output (N.O. or
N.C) to connect alarm devices. With this function, the Dome Camera can
cooperate with alarm system to catch events’ images. For wiring, please refer to
the installation guide and/or qualified service personnel. Adjustable alarm
parameters are listed below.
• ALARM PIN
The Dome Camera provides 8 alarm inputs and 1 output (N.O. or N.C.).
Select an alarm connector which you want to set its alarm-related
parameters with this item, and then set its alarm-related parameters in the
Alarm Setting menu. For alarm pin definitions, please refer to 2.6 22-Pin
Connector Definition or the installation guide.
NOTE: If two or more alarm pins are triggered at the same time,
smaller alarm pin number will have higher priority of being handled.
For example, if Alarm-1 and Alarm-3 are triggered simultaneously,
only Alarm-1 will actually be handled.
• ALARM SWITCH
The item is used to enable or disable the selected alarm pin function. Use
the left/right direction keys on the control keyboard to change the setting.
• ALARM TYPE
There are two kinds of alarm types: Normal Open and Normal Close, which
are illustrated as below. Select an alarm type that corresponds with the
alarm application.
ALARM SETTING
ALARM PIN 1
ALARM SWITCH OFF
ALARM TYPE N.C.
ALARM ACTION PRESET
PRESET POINT 001
DWELL TIME ALWAYS
EXIT YES