User`s manual
User’s Manual
45
NOTE: Flip setting is manual-controlled only. If a Preset or a point
for other function (ex. Sequence) is set in the position that can only
be reached through FLIP motion, when Flip is off, the position
cannot be reached anymore.
OFF
Select this item to disable the flip function.
NOTE: To make the Dome Camera tilt between a specific range,
such as -10° to +100° or -10° ~ +190°, please go to ANGLE
ADJUSTER (see next section) to set the angle range of tilt.
Otherwise, the Dome Camera will tilt 90° as the default setting.
• ANGLE ADJUSTER
The item is for adjusting the angle range of tilt motion. The Range of the tilt
motion varies in different FLIP modes: the angle ranges from -10° to +100°
in the M.E. FLIP and FLIP OFF modes, and from -10° ~ +190° in the IMAGE
FLIP mode.
• SPEED BY ZOOM
If the item is set to <ON>, the pan/tilt speed will be automatically adjusted
by internal algorithm when zooming. The larger zoom ratio leads to the
lower rotating speed.
• AUTO CALI. (Auto Calibration)
There are one horizontal point and one vertical infrared rays check point in
each Dome Camera. During installation or maintenance, the Dome
Camera’s position may be moved. Therefore, the relative distance between
the original set point and the check point will be changed. If the Auto
Calibration function is enabled, the Dome Camera will automatically detect
the matter and reset the horizontal point back to the original position.
ANGLE ADJUSTER
ADJUST MIN ANGLE -10DEG
ADJUST MAX ANGLE 100DEG
EXIT + SET YES