TROUBLE SHOOTING GUIDE
NOITCA EVITCERROCSELBUORT
Heater Will Not Light ;
htiw knat lliF .1ytpme si knat leuF .1 water-clear 1-K kerosene or
red dyed 1-K kerosene.
2. Water present in kerosene 2. Drain tank. Remove wick assembly & replace wick.
Reinstall wick assembly. Fill tank with water-clear
1-K kerosene or red dyed 1-K kerosene.
3. Igniter plug Fails to Glow 3.
Replace batteries if necessary. Be sure batteries are installed
properly. Replace igniter plug. Check for broken or disconnected wire.
4. Igniter plug makes contact with 4. Lower wick using wick adjuster knob until igniter plug
.kciw fo pot htiw tcatnoc sekamkciw fo edis
Heater Produces Smoke or Odor ;
.1hgih oot si emalF .1 Using wick adjuster knob, lower wick to desired 1/2" flame.
2. Heater is in an air draft 2. Move heater out of air draft.
ti litnu edis ot edis morf renrub etator ,bonk renrub gnisU .3level ton si renruB .3
seats properly over wick.
4. Carbon or tar built up on wick 4. Perform "Carbon Removal / Dry Burning" procedure.
Replace wick if necessary.
5. Contaminated kerosene 5. Drain tank. Remove wick assembly & replace wick.
Reinstall wick assembly. Fill tank with water-clear
1-K kerosene or red dyed 1-K kerosene.
Flame Flickers or Dies ;
1. Water present in kerosene 1. Drain tank. Remove wick assembly & replace wick.
Reinstall wick assembly. Fill tank with water-clear
1-K kerosene or red dyed 1-K kerosene.
2. Carbon or tar built up on wick 2. Perform "Carbon Removal / Dry Burning" procedure.
Replace wick if necessary.
Wick Burning Down Excessively ;
1. Dangerous, volatile fuel 1. Drain and clean tank
mixed with kerosene
Remove and replace wick
(gasoline, benzene, alcohol,
Fill tank with water-clear 1-K kerosene
white gas, paint thinner, camp, or red dyed 1-K kerosene.
stove fuel, oil compound)
Wick Adjuster Sticks ;
1. Water present in kerosene 1. Drain tank. Remove wick assembly & replace wick.
Reinstall wick assembly. Fill tank with water-clear
1-K kerosene or red dyed 1-K kerosene.
2. Carbon or tar built up 2. Perform "Carbon Removal / Dry Burning" procedure.
Replace wick if necessary.
Heater is enveloped in flames ;
Call Fire Department.
Exit quickly and warn others.
DO NOT: Move heater, try to smother fire, or put water
on fire.