Instructions / Assembly

3
PROPANE CONSTRUCTION HEATER
SPECIFICATIONS
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
Model No. FA43 Series
Input Rang
37,000 BTU/hr (12.6 KW) Min.
43,000 BTU/hr (10.84 KW) Max.
Type of Gas Propane
Gas Supply Pressure to Regulator Maximum Cylinder Pressure
Minimum (for purpose of Input Adjustment) 5 psig
Manifold Pressure 11” W.C
Gas Consumpon
1.71lbs/hr 0.78 kg/hr
2.00lbs/hr 0.91 kg/hr
Electrical Input 120V, 60Hz, 1Ø
Amperage Load 1.75 amps
Fan
Unload
Load
3375rpm
3100rpm
Ignion Piezo/Manual Spark
Spark Gap 0.16” (4mm)
Size (LxWxH)
16.2”x8.3”x11.9”
(41.2x21.1x30.2)cm
USA 8-Hr Time weighted average
(OSHA 29 CFR 1926.55 App A)
CO 50 ppm
CO
2
5000 ppm
NO
2
USA – Ceiling Limit
(Short Term Exposure Limit = 15 minutes)
CO
CO
2
NO
2
5 ppm
Canada 8-hr time weighted average
WorkSafe BC OHS Guidelines Part 5.1
and Ontario Workplaces Reg 833
25 ppm
5000 ppm
3 ppm (Reg 833)
Canada STEL (15 minutes Reg 833/1 hour
WSBC) WorkSafe BC OHS Guidelines Part
5.1 and Ontario Workplaces Reg 833
100 ppm
15000 ppm (WSBC)
30000 ppm (Reg 833)
1.0 ppm (WorkSafeBC)
5.0 ppm (Reg 833)
Ensure that the ow of combustion and ventilation air exchange cannot become obstructed.
As the building ‘tightens up’ during the construction phases ventilation may need to be increased.