Installation Guide
10
SELECTION SWITCH
Using the SELECTION SWITCH, you can control the heating output:
I for 3000W, II for 4000W, III for 5000W.
The heater must be properly installed before it is used.
WARNING
OPERATING INSTRUCTIONS
5000W 3000W 4000W
Control Panel
Power Indicator
(Yellow)
Caution Indicator
(Red)
Thermostat Switch (3000W
4000W 5000W)
NOTE: When the thermal cut-out is activated, the caution indicator will turn red.
In this case, immediately turn the heater OFF and inspect for any objects on or
adjacent to the heater that may cause high temperatures. DO NOT OPERATE
THE HEATER WITH THE CAUTION INDICATOIR GLOWING RED.
ADJUSTING AIR FLOW DIRECTION
1. To turn the unit when it has been installed with a single lag bolt (as shown in
î‚¿gure 4a), simply turn the entire heater as needed. The unit cannot be turned
horizontally if it has been installed with 2 lag bolts.
2. To tilt the unit vertically, loosen the bracket screws (see Figure 5 on page 6).
THERMAL CUT-OUT
The heater will automatically shut off when parts of it overheat. The heater
will turn ON again when the abnormal temperature returns to normal levels.
Should the unit overheat and cause the thermal cut-out to cycle, the cause of
the overheating should be determined and corrective action taken before further
operation.
SETTING THE THERMOSTAT
1) Rotate thermostat knob clockwise to desired position, POWER INDICATOR
will turn yellow.
2) After room reaches desired comfort level the heater will turn off. Heater will
cycle on and off to maintain room temperature.