ASSEMBLY INSTRUCTIONS
CHECKING FOR LEAKS
After all connections are made, check all connections and ttings on the natural gas quick connector,
gas hose and manifold for leaks with a water and soap solution.
To prevent re or explosion while testing for a leak:
Always perform leak test prior to lighting the grill.
• Do not smoke while testing for a leak.
Always perform leak tests outdoors in a well-ventilated area.
Do not use any source of ame while testing for leaks.
• Do not use the grill until any and all leaks are corrected.
• If you are unable to correct a leak, close the natural gas shut-off and call a gas appliance service
agency.
PERFORM LEAK TEST
Prepare leak test solution by combining 1 part liquid dish soap with 3 parts water.
Total solution required is approximately 2 - 3 ounces (70 - 90 ml).
Put leak test solution in a spray bottle.
Ensure all control knobs are in the ‘OFF’ position.
Connect the gas hose to the gas supply.
Open the gas shut-off valve.
Spray leak test solution on all gas carrying connections and ttings. Presence of bubbles at areas
of applied test solution indicates a gas leak. If leaks are detected or you smell or hear gas, shut off
the gas supply valve immediately and repair or replace the defective part. Do not use the grill until all
leaks are corrected.
ALL INSTRUCTIONS AND SAFEGUARDS ON THIS PAGE MUST BE FOLLOWED TO
PREVENT FIRE, DAMAGE AND/OR INJURY.
In the connection process, make sure:
The gas supply hose does not come in contact or remain in contact with the rebox.
Only use the hose assembly provided! If a replacement is necessary, please call
our customer service center. Do not use replacement parts that are not intended for this grill.
WARNING
WARNING