INDOOR/OUTDOOR PRODUCTS KEROSENE PORTABLE FORCED AIR HEATERS “USER’S MANUAL AND OPERATING INSTRUCTIONS” COMPLIES WITH UL733 AND ANSI A10.10-1998 CAN/CSA/ B140.0-03 AND CSA B140.8-1967 MODEL: KFA50H, KFA80H, KFA135H, KFA220H Before the first use of this heater, please read this USER’S MANUAL very carefully. This USER’S MANUAL has been designed to instruct you as to the proper manner in which to assemble, maintain, store, and most importantly, how to operate the heater in a safe and efficient manner.
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! DANGER: IMPROPER USE OF THIS HEATER CAN RESULT IN SERIOUS INJURY OR DEATH FROM BURNS, FIRE, EXPLOSION, ELECTRICAL SHOCK AND/OR CARBON MONOXIDE POISONING. WARNINGS: 1. RISK OF INDOOR AIR POLLUTION! • • • • Use this heater only in well ventilated areas. Provide at least a three-square foot (2,800 sq. cm.) opening of fresh outside air for each 100,000 BTU/hr. of heater rating.
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! CONTENTS OF USER’S MANUAL ITEM PRECAUTIONS - SAFETY GUIDE.......................................................... 1. INTRODUCTION................................................................................ 2. FEATURES........................................................................................... 3. UNPACKING AND ASSEMBLY........................................................ 4. FUELS........................................................
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! Front Handle Upper Shell Hot Air Outlet Rear Handle Shell Lower Cord Wrap Fuel Gauge Fuel Cap Side Cover Lamp Thermostat Knob Room Temp. Display Pressure Gauge Fan Guard Power Cord (Piggy Back) Power/Reset Switch 10” Flat Free Wheel Fuel Drain Bolt Figure 2. KFA135H MODEL Front Handle Upper Shell Hot Air Outlet Rear Handle Shell Lower Cord Wrap Fuel Gauge Fuel Cap BTU Control Switch Pressure Gauge Side Cover Lamp Thermostat Knob Room Temp.
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 3. UNPACKING AND ASSEMBLY 1. REMOVE THE HEATER AND ALL PACKING MATERIALS FROM THE BOX. (Fig. 4 and 5) NOTE : Save the shipping carton and packing materials for future storage. Wheel Support Frame Wheel Threaded Axle Front Handle Rear Handle Handle Cord Wrap Hardware kit : HW-KFA1016 KFA50H KFA80H No No No No No Yes 50H No/80H Yes No KFA135H KFA220H Yes Yes Yes Yes Yes No Yes Yes Yes Yes Yes Yes Yes No Yes Yes Figure 4.
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 2. ASSEMBLY For KFA50H/80H Models only (Assembly time for this product is 3 minutes) Handle Remove Screws Screw Front Guard Wedged Portion Slit Hole Tools Required • Medium Phillips Screwdriver. 1) Lift front guard for arrow direction and make sure that guard’s wedged portion fits into the slit hole on the upper housing. 2) Remove the pre-assembled screws on the shell upper and side cover.
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! Screw Cap Nut S Front Handle Rear Handle Hot Air Outlet Cord Wrap Flange Screw Fuel Tank Flange Air Inlet Wheel Support Frame Threaded Axle Nut Wheel Wheel Bushing Cap Nut L Figure 7. Assembling Handle, Wheel and Cord Wrap CAUTION: DO NOT OPERATE heater without support frame assembled to tank. NOTE: Heater should be inspected before each use, and at least annually by a qualified service person. 4.
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 5. OVERVIEW OF HEATER’S DESIGN Fuel System: This heater is equipped with an electric air pump that forces air through the air line connected to the fuel intake and then through a nozzle in the burner head. When the air passes in front of the fuel intake it causes fuel to rise from the tank and into the burner nozzle. This fuel and air mixture is then sprayed into the combustion chamber in a fine mist.
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 6. FUELING YOUR HEATER NEVER FILL THE HEATER FUEL TANK IN THE LIVING SPACE : FILL THE TANK OUTDOORS. DO NOT OVERFILL YOUR HEATER AND BE SURE HEATER IS LEVELED. IMPORTANT NOTICE REGARDING FIRST IGNITION OF HEATER : The first time you light the heater, it should be done outdoors. This allows the oils, etc. used in manufacturing the heater to burn off outside. WARNING!! : NEVER REFILL HEATER FUEL TANK WHEN HEATER IS OPERATING OR STILL HOT. 7. OPERATION A.
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! Room Temp. Display Lamp Btu Control Switch Lamp Thermostat Control Knob (80H MODEL ONLY) LED Power Switch KFA50H/80H Models Thermostat Control Knob BTU Control Switch Push to “HIGH” Push to “LOW” LED Power Switch KFA135H/220H Models Relief Valve Fan Guard Figure 8. Controls for All Models NOTICE : The major electrical components of this heater are protected by a safety fuse mounted to the PCBboard.
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 9. MAINTENANCE WARNING!! : NEVER SERVICE HEATER WHILE IT IS PLUGGED IN OR WHILE HOT! USE ORIGINAL EQUIPMENT REPLACEMENT PARTS. Use of third party or other alternate components will void warranty and may cause unsafe operating conditions. A.) FUEL TANK FLUSH EVERY 200 HOURS OF OPERATION OR Screw Upper Shell AS NEEDED (SEE STORAGE, PAGE 9) Air Intake Filter B.
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! E.) NOZZLE REMOVE DIRT IN NOZZLE AS NEEDED (SEE PAGE 16). (For KFA50H /80H/135H Models Only) - Remove upper shell (See page 10). - Remove fan blade (See page 10). - Remove fuel and air line hoses from nozzle adaptor. - Remove ignitor wire from spark plug. - Remove spark plug from nozzle adaptor using medium phillips screwdriver. - Turn nozzle adaptor 1/9 turn(40°) to counter clock wise and pull toward motor to remove.
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! F.) SPARK PLUG CLEAN AND REGAP EVERY 600 HOURS GAP GAP OPERATION OR REPLACE AS NEEDED. (For KFA50H/80H/135H Models Only) - Remove upper shell (See page 10). Nozzle Adaptor - Remove fan (See page 10). Spark Plug Screw - Remove ignitor wire from spark plug. - Remove spark plug from nozzle adaptor using medium Spark Plug phillips screwdriver. - Clean and regap spark plug electrodes to 3.5mm gap. Ignitor Wire GAP (0.138”) 3.
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! H.) FUEL FILTER CLEAN OR REPLACE TWICE A HEATING SEASON OR AS NEEDED. - Remove side cover screws using medium phillips screwdriver. - Disconnect switch wires from power switch and remove side cover. - Pull fuel line off fuel filter neck. - Turn fuel filter 90˚ to counter clockwise and pull to remove (KFA50H/80H Models only). - Turn fuel filter 90˚ to clockwise and pull to remove (KFA135H/220H Models only).
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 10. REPLACING FUSE NOTICE : This heater is fuse protected. If your heater fails to ignite, DO NOT RETURN YOUR HEATER TO THE STORE. Please follow the simple instructions below to inspect and change the fuse. PROCEDURE FOR REPLACING FUSE WARNING : SHOCK HAZARD To prevent personal injury, unplug the power cord before replacing fuse. 1. Unplug heater. 2. 3. 4. 5. Remove side cover screws using medium phillips screw driver.
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 11. TROUBLESHOOTING GUIDE TROUBLE POSSIBLE CAUSE Heater ignites but MAIN PCB assembly shuts heater off after a short period of time. (Indicator Lamp is flickering and room temp. display indicates “ E1 “) 1. Wrong pump pressure. 2. Dirty Air Output,Air Intake or Lint Filter. 3. Dirty Fuel Filter. 4. Dirt in Nozzle. 5. Dirty Photocell Lens. 6. Photocell Assembly not Properly installed.(Not seeing the flame) 7.
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 12.
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 16.7"(424mm) 13. SPECIFICATIONS 32.0"(813mm) 11.7"(297mm) KFA50H/80H Models H D KFA135H KFA220H D 41.9”(1,063 mm) 47.4”(1,205 mm) W 21.5”(547 mm) 23.1”(587 mm) H 32.4”(824 mm) 33.5”(850 mm) W KFA135H/220H Models MODEL BTU/Hr. Fuel Consumption - Gal./Hr( ./Hr) Fuel Tank Capacity - Gal.( ) Fuel Tank Capacity - Gal.(kgf/cm2) Volt/Hz Amps. Phase Size(D×W×H), Inch(mm) Weight Lbs.
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 14. EXPLODED PARTS DRAWING (KFA50H//80H/135H Models Only) NOTE : SPECIFY MODEL NUMBER AND PART NUMBER WHEN ORDERING PARTS.
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 15. PARTS LIST (KFA50H/80H/135H Models Only) KEY NO. DESCRIPTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 22-1 22-2 22-3 22-4 22-5 22-6 22-7 22-8 23 24 25 25-1 25-2 25-3 25-4 25-5 25-6 25-7 Fuel Tank Assmebly Fuel Drain-Bolt Fuel Gauge Fuel Filter Assmbly Fuel Cap Power Cord Button Support Display P.C.
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 15. PARTS LIST (KFA50H/80H/135H Models Only) KEY NO. 25-8 25-9 25-10 25-11 25-12 25-13 25-14 25-15 25-16 25-17 25-18 25-19 25-20 25-21 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 DESCRIPTION Rotor Blade Insert End Pump Cover Elbow Lint Filter Bolt Flange Output Filter End Filter Cover Ball Spring Adjusting Screw Bolt Flange Intake Filter Fan Assembly Bolt Headless Hex Socket Pressure Gauge Main P.C.
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 14. EXPLODED PARTS DRAWING (KFA220H Model Only) NOTE : SPECIFY MODEL NUMBER AND PART NUMBER WHEN ORDERING PARTS.
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 15. PARTS LIST (KFA220H Model Only) KEY NO.
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 15. PARTS LIST (KFA220H Model Only) KEY NO. 21-15 21-16 21-17 21-18 21-19 21-20 21-21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 KEY NO. 1 2 3 PART NO. KFA220H DESCRIPTION Quantity See SP-KFA1005 3221-0076-00 See SP-KFA10103 See SP-KFA10103 See SP-KFA10103 4329-0016-00 See SP-KFA10052 2154-0007-00 4323-0004-00 3740-0049-00 2154-0070-00 215A-0074-00 4312-0046-00 39E0-0071-00 3121-0499-33 39A0-0191-00 3231-0113-00 4319-0015-00 3121-0354-00 .
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 15. PARTS LIST (WHEELS AND HANDLE) 1) KFA50H / KFA80H MODELS KEY NO. 1 2 PART NO. DESCRIPTION KFA50H 3231-0073-00 - Handle Cord Wrap 1 KFA80H 3231-0073-00 3221-0041-00 1 QUANTITY 1 2 2 2 2) KFA135H / KFA220H MODELS KEY NO.
Warranty LIMITED WARRANTY: This limited warranty is extended to the original retail purchaser of this Forced Air/Convection/Radiant Heater and warrants against any defect in materials and workmanship for a period of one (1) year from the date of retail sale.GHP Group, Inc., at it’s option, will either provide replacement parts or replace or repair the unit, when properly returned to the retailer where purchased or one of our service centers as directed by GHP Group,Inc.
WARRANTY REGISTRATION IMPORTANT: We urge you to fill out your warranty registration card within fourteen (14) days of date of purchase. You can also register your warranty on the internet at www.ghpgroupinc.com. Complete the entire serial number. Retain this portion of the card for your records. GHP Group, Inc. 6440 W Howard St Niles, IL 60714-3302 Tel: (877) 447-4768 www.ghpgroupinc.com SAVE THIS CARD! Place Postage Stamp Here GHP Group, Inc.