Instructions / Assembly

6
Wiring Diagrams
Dyna-Glo Delux Operating Instructions and Parts Manual
Dyna-Glo
®
Delux Natural Gas
Construction Heater
RMC-FA150NGDGD
For Technical Support or Troubleshooting, Call: 1-877-447-4768, 8:30 am - 4:30 pm CST www.ghpgroupinc.com
Figure 6 – Wiring Diagram
E
N
G
L
I
S
H
Gas
Valve
Yellow
White
Black
Blue
White
Motor
Black
White
Red
White
Yellow
Green
Black
White
Line
Neut
Valve
Ground
Line Cord
Flame
Control
Flame
Control
Flame Control
High Limit
Switch
on / off
Thermostat
Spark Plug
Orange
If any original wiring as supplied with the heater must be
replaced, it must be replaced with type AWG105°C wire or its
equivalent except as indicated (*Type SF2-200, **SGI-250°C)
Green
Flame
Control
Black
Back
Pressure
Switch
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!