Instructions / Assembly

PROFESSIONAL GRADE
section. Repair any leaks immediately.
Maintenance (Continued)
2. Always keep heater clean. Clean
the heater annually, or as often as
needed to remove any dust or debris.
When the heater becomes dirty, wipe
it down with a damp cloth.
3. Keep the inside of the heater
free from foreign objects and
combustibles.
4. Have the heater inspected annually
by a qualified service person.
SERVICE PROCEDURES
WARNING
Never service heater
while hot, operating
or connected to the gas supply. Severe
burns or electrical shock may occur.
REMOVING PROTECTIVE COVER
1. Remove base lower at the bottom of
the heater.
2. Remove fan guard.
FAN
IMPORTANT: Always remove the fan
from the motor shaft before removing
the motor assembly from the heater.
This will help prevent damage to the
fan.
1. Remove base lower.
2. Remove fan guard.
3. Remove base.
4. Disconnect lead wires attached to
the motor.
5. Remove motor assembly.
6. Loosen fan setscrew using a 1/8” hex
wrench, and remove fan.
7. Using a soft cloth moistened with
kerosene or a cleaning solvent,
carefully clean the fan blades
making sure not to bend them.
8. Dry fan with clean cloth.
9. Assemble fan on motor shaft and
tighten hex nuts firmly (be careful
not to overtighten).
10. Reconnect lead wires as shown in
the Wiring Diagram (Figure 6).
11. Reassemble base, fan guard and
base lower.
IGNITOR
The only maintenance necessary for
the ignitor is to be sure that the gap
between the electrodes is kept between
.10” and .15”. The ignitor is accessible
through the combustion chamber.
Storage
CAUTION
Always disconnect
heater from gas
supply.
1. Replace the plastic caps over the
fittings they were installed when you
originally unpacked your heater.
2. Store the heater in a safe, clean and
dry location.
3. When removing the heater from
storage, always check inside of the
heater for any foreign objects left
by spiders or small animals. Keep
the inside of the heater clean from
foreign objects and combustibles.
5
Washer
Figure 5 – Fan Motor Shaft, Hex Nut
Location
Fan
Hex Nut
Motor
Fan Guard
Base
Base Lower
Figure 4 – Protective Cover Removal
Model RMC-FA150NGDGD
Dyna-Glo Delux Operating Instructions and Parts Manual
For Technical Support or Troubleshooting, Call: 1-877-447-4768, 8:30 am - 4:30 pm CST www.ghpgroupinc.com
E
N
G
L
I
S
H
NEVER LEAVE THE HEATER