User`s guide
MADYMO Coupling Manual Release 7.5
shell element ID list for coupling:
1 2 3 4
input summary including part IDs:
number of part IDs = 9
number of unique nodal points = 1
number of shell elements = 4
number of solid elements = 0
number of solid-shell elements = 0
Accompanying reprint file:
COUPLING
FE_MODEL ...............................: /10/3 ( /coupling_model/fe_model )
NUMBER OF NODES : 9
NUMBER OF PARTS : 1
PART ID (FROM COUPLED PROGRAM) : 92
THICKNESS : 1.0000E-01
BULK MODULUS : 2.5000E+07
NUMBER OF ELEMENTS : 4
NUMBER OF TRIADS : 0
NUMBER OF QUADS : 4
NUMBER OF SOLIDS : 0
5.4 Coupling on Microsoft Windows platform
The new MPP coupling is also available on Microsoft Windows for LS-DYNA. The procedure
to start a coupling calculation is:
1. Set the environment variables MADLIC_LICENSE_FILE and environment variables nec-
essary to execute the LS-DYNA software.
2. Open two command shells and go to the directory where the input files for MADYMO
and LS-DYNA are located. All input files must reside in the same directory, otherwise
the communication between both programs will fail.
3. start MADYMO in command window 1 with the command:
"<madymo_dir>\<platform_id>\bin\madymo_cli.exe" -coupling socket
<input_xml_file>
4. start LS-DYNA in command window 2 with the command:
"<lsdyna_dir>\lsdyna.exe" y=madymo i=<input_file>
5.5 Restart
For more general information on restart, see the LS-DYNA user manual and the MADYMO
Reference Manual
. Restart is supported in MPP coupling for both LS-DYNA and MPP-DYNA
23