Installation Sheet
- 5 -
11
HOLE SIZE IN WALL
1-5/16" MIN. (33 mm)
1-3/4" MAX. (45 mm).
10
3
M965648
ALIGN FAUCET WITH SHANKS
• Insert FAUCET (11) inlets into OFFSET SHANKS (10). If FAUCET (11) cannot be installed,
adjust both OFFSET SHANKS (10) inwards/outwards until the faucet can be installed and is level.
• Remove faucet.
ALIGN OFFSET SHANKS
HOT
PIPE PLUG
COLD
8mm
HEX WRENCH
8"
(203mm)
10
10
10
• Turn off water supplies. Remove the two PIPE PLUGS. Apply SEALING TAPE to the end of each OFFSET
SHANK (10) and thread into each ELBOW (9) with a 8mm HEX WRENCH.
• Check that the OFFSET SHANKS (10) are level and centers are 8" (203mm) apart. Distance needs to
be maintained accurately.
• Adjust each OFFSET SHANK (10) if needed with the 8mm HEX WRENCH until
OFFSET SHANKS (10) are level.
WALL-MOUNT INSTALLATION