Installation Sheet
- 4 -
1
M965648
2
INSTALL PIPE PLUGS
• Apply SEALING TAPE to PIPE PLUGS and thread into the ELBOWS (9).
Test all concealed piping for leaks.
• Finish all wall construction. The faucet holes through the wall are 1-5/16” MIN. (33mm) and a
1-3/4” MAX. (45mm) with centers 8” apart.
WALL MOUNT INSTALLATION
9
9
HOT
COLD
CROSS
BRACE
FINISHED WALL
FINISHED FLOOR
8"
(203mm)
AS
DESIRED
1-1/4
13/16" MIN. (19.5 mm)
" MAX. (32.2 mm)
9
9
HOT
PIPE PLUGS
PIPE PLUGS
COLD
HOLE SIZE IN WALL
1-5/16" MIN. (33 mm)
1-3/4" MAX. (45 mm).
FINISHED WALL
1-1/4
13/16" MIN. (19.5 mm)
" MAX. (32.2 mm)
WALL-MOUNT INSTALLATION
• Determine where the nished wall location will be. This measurement is very important!
Note: The rough-in measurement from the end of the elbow to the nished wall is a minimum of
13/16" (19mm) and a maximum of 1-1/4" (32.2mm).
• Determine the height of the faucet from the nished oor and mark the center line of each
ELBOW (9) exactly 8" apart on the wood support. Attach the two ELBOWS (9) to the wood
support with wood screws on each center line. Check that
the ELBOWS (9) are level.