INSTALL HANDLE
• Remove PLASTER GUARDS and unthread ROUGH-IN NIPPLE (1).
• Inspect that SPOUT NIPPLE O-RINGS (2 & 3) are seated in the grooves of SPOUT NIPPLE (4).
• Thread SPOUT NIPPLE (4) into VALVE BODY (5). Tighten SPOUT NIPPLE (4) to VALVE BODY (5).
• Thread ESCUTCHEON MOUNT (6) onto SPOUT NIPPLE (4) until it engages the O-RING (2).
• Make sure GASKET (7) is in place. ESCUTCHEON MOUNT (6) Flush against nished wall.
• Push SPOUT 8) with SPOUT O-RINGS (9) into ESCUTCHEON MOUNT (6)
until seated against stop.
• Determine where the nished wall location will be. This measurement
is very important! Note: The rough-in measurement from the nished
wall is; 1-9/16" (40 mm) minimum and 2-7/16" (62 mm) maximum.
This is a 7/8" (22 mm) tolerance. See rough-in illustration.
• Secure WALL BRACKET (1) to cross brace of wall structure
at required height using six wood screws.
• Mount VALVE BODY (1) to WALL BRACKET (2) as shown. Level and tighten
SET SCREWS (3) to secure VALVE BODY (1) to WALL BRACKET (2).
• Connect HOT water supply to LEFT INLET UNION (4) and COLD water supply
to RIGHT INLET UNION (5). Pipe connections are 1/2” NPT. Use sealant or
Teon tape on pipe connections. Do not solder directly to valve body.
• With valves closed open supply lines and check for leaks. Remove
PLASTER GUARDS (6) and open both valves and check for leaks.
• Close both valves and turn off water supplies. Replace
PLASTER GUARDS (6) and nish wall construction.
INSTALL WALL BRACKET
INSTALL VALVE BODY
WOOD SCREWS
CROSS BRACE
WALL STUDS
1
16"
(406 mm)
HOT
COLD
6
6
5
4
3
2
1
2
2
4
4
8
6
9
O-RING
7
GASKET
1 1
5
3
Figure A