Installation Sheet
- 3 -
M965713 Rev. 1.1 (3/17)
3
4
5
MAKE WATER SUPPLY AND WASTE CONNECTIONS
• With HANDLE (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
• Operate HANDLE (1) to ush water lines thoroughly.
CHECK DRAIN CONNECTIONS
• Operate POP-UP KNOB (4) and ll lavatory with water.
Check that DRAIN STOPPER (5) makes a good seal
and retains water in SINK. If DRAIN STOPPER (5)
does not seal properly, adjust POP-UP ROD (3).
• Release POP-UP KNOB (4) down and check all drain
connections and “P” trap for leaks.
Tighten
if necessary.
TEST INSTALLED FITTING
• Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies.
Connection on tting supplies are 3/8" compression. Connect
left SUPPLY (1) to Hot (Marked with a Red Band) and right supply
to COLD (2) wall supply.
• Faucet supplies are 20" long from faucet base.
Note: If additional supply length is required, installer must
purchase additional parts separately.
Impor tant: If SUPPLY HOSES (1, 2) are to long, loop as
illustrated to avoid kinkin
1
APPROX. 20"
2
COLD
HOT
3/8" COMPRESSION
RED
BAND
BLUE
BAND
2
5
4
2
“P” TRAP
WASTE
OUTLET
3
1
OFF
ON
COLD
HOT
SERVICE
CAUTION
Turn off hot and cold water
supplies before beginning.
1
4
2
3
9
10
11
8
7
5
6
• To remove or replace cartidge:
— Turn valve to OFF position.
— Pull out PLUG BUTTON (1) and loosen HANDLE SCREW (2).
— Pull off HANDLE (3).
— Unthread and remove CARTRIDGE NUT (4) with CARTRIDGE RING
NUT KEY (9). For Polished Chrome
— Pull CARTRIDGE COVER (10) off and unthread CARTRIDGE RING NUT (11).
For Brushed Nickel and Matte Black
— Pull out CARTRIDGE (5).
— Inspect CARTRIDGE (5) and O-RINGS (6) for debris and clean if necessary.
— Clean MANIFOLD (7) and rinse clean.
— Reinstall CARTRIDGE (5) and O-RINGS (6) onto MANIFOLD (7).
— Reinstall CARTRIDGE NUT (4), CARTRIDGE RING NUT KEY (9) and
HANDLE ASSEMBLY (3). For Polished Chrome
— Reinstall CARTRIDGE RING NUT (11), CARTRIDGE COVER (10) and
HANDLE ASSEMBLY (3). For Brushed Nickel and Matte Black
• If spout drips, operate handle several times from OFF to ON and HOT to COLD position. Do not force handle.
• AERATOR (8) may accumulate debris causing distorted or reduced water ow. Remove AERATOR (8) and and/or water
supplies and rinse clean.