Installation Sheet

- 5 -
12
13
14
CONNECT DRAIN
TEST INSTALLED FITTING
CHECK DRAIN CONNECTIONS
• Connect 1-1/4" (32 mm) O.D. tailpiece on POP-UP DRAIN to waste outlet.
Operate POP-UP KNOB (5) and ll Sink with water. Check
that DRAIN STOPPER (4) makes a good seal and retains
water in Sink. If STOPPER (4) does not seal properly, please
refer to “Troubleshooting Guide” in these instructions.
Push POP-UP KNOB (5) down and check all drain connections
and “P” trap for leaks. Tighten if necessary.
TO CLEAN AERATOR
AERATOR (3) may accumulate dirt causing distorted
and reduced water ow. Unscrew and remove
AERATOR (3) and rinse clean.
Replace AERATOR (3) and operate handles several times
from OFF to ON position. Do not force, handles turn only 90˚.
M965705 Rev. 1.1 (2/17)
WASTE
OUTLET
1-1/4" (32 mm)
O.D. TAILPIECE
2
3
HOT
2
COLD
4
“P” TRAP
WASTE
OUTLET
1
1
5
With HANDLES (1) in OFF position, turn on WATER SUPPLIES (2)
and check all connections for leaks.
• Remove AERATOR (3).
• Operate both HANDLES (1) to ush water lines thoroughly.
• Replace AERATOR (3).