Installation Sheet
- 3 -
M965701 Rev. 1.1 (5/17)
3
4
INSTALL HANDLES
• Turn VALVE STEMS (15) to off position.
•  Align LEVER HANDLES (16) as shown and install onto ADAPTERS (10).Tighten SET SCREW (17) with 
HEX WRENCH (14) supplied. Install PLUG BUTTONS (18).
INSTALL WALL SPOUT
•  Twist and pull off PLASTER GUARDS (1). Thread counter clock-wise ROUGH-IN NIPPLE (2) with a at blade screwdriver 
 and remove.
• Inspect that SPOUT NIPPLE O-RINGS (3 & 4) are seated in the grooves of SPOUT NIPPLE (5). See View “A”.
• Thread SPOUT NIPPLE (5) into VALVE BODY (6) and tighten until O-RING (3) is fully seated against VALVE BODY (6).
• Mount WALL ESCUTCHEON (9). Thread ADAPTERS (10) onto VALVE (11) until WALL ESCUTCHEON (9) is ush 
against nished wall. 
• Inspect that ADAPTER O-RINGS (3, 4) are seated in the grooves of ADAPTER (5). See View “A”. Install ADAPTER (5) 
into spout outlet and tighten with wrench. Thread SPOUT ADAPTER (7) onto ADAPTER (5) so that the groove 
extends 9/16" beyond face of ESCUTCHEON. See View “B”.
• Push SPOUT (12) onto SPOUT ADAPTER (7) until ush against WALL ESCUTCHEON (9). If SPOUT is not against  
WALL ESCUTCHEON (9) pull spout off and adjust SPOUT ADAPTER (10).
• Tighten SET SCREW (13) with HEX WRENCH (14) supplied.
13 
17 
14
4 
4 
5 
3 
2
1
1
View A
View B
VIEW "A"
VIEW "B"
VALVE STEM
OFF
OFF
VALVE
STEM
5
6
7
11
9
11
10
12
10
16
16
8 SPOUT
O-RING 
18
15
15
14
9/16"
(14mm)
GROOVE
FINISHED
WALL
GROOVE
ESCUTCHEON