Installation Sheet

- 5 -
M965700 Rev. 1.0 (3/17)
10
• With HANDLE (1) in OFF position, turn on WATER SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3). First loosen aerator set screw with HEX WRENCH (4) supplied. Pull out AERATOR (3) with
AERATOR KEY (5).
• Operate HANDLE (1) to ush water lines thoroughly.
• Replace AERATOR (3) and tighten set screw.
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (6) and ll lavatory with water. Check that DRAIN STOPPER (7) makes a good seal and retains
water in Sink. If DRAIN STOPPER (7) does not seal properly, please refer to Troubleshooting section in these instructions.
• Release POP-UP KNOB (6) down and check all drain connections and “P” trap for leaks. Tighten if necessary.
TEST INSTALLED FITTING
6
3
4
1
5
OFF
ON
HOT
COLD
“P” TRAP
WASTE
OUTLET
2
2
7