SPECIFICATIONS
Service: Compatible gases and liquids.
Wetted Materials: Brass connection,
bronze tube.
Housing: Chrome plated steel.
Lens: Polycarbonate.
Accuracy: ± 3-2-3% FS.
Pressure Limits: FS range.
Temperature Limits: -4 to 140°F (-20
to 60°C).
Size: 2.5˝ (63 mm).
Process Connections: 1/4˝ male NPT.
Weight: 8 oz (227 g).
2.5˝ LOW PRESSURE GAGE
3-2-3% Full-Scale Accuracy in a 2.5” Gage
The Series LPG5 2.5˝ Low Pressure Gage offers top of the line performance for
pressure applications from 10 in w.c. to 10 psi. The LPG5 gages possess dual scales
with 3-2-3% full-scale accuracy on a 2.5˝ dial. Units are made with a chrome plated
steel housing and brass wetted parts. Units can withstand temperatures of -4 to 140°F
(-20 to 60°C). This series is meant for the measurement of low pressures of gases and
liquids and is ideal for air ow indication, liquid level and draft measurement. Series
LPG5 gages are available with either a bottom or back connection option.
FEATURES/BENEFITS
• Chrome plated steel housing and brass wetted parts resist ambient for longer
service life in harsh environments
• Low pressure gage provides a selection to meet specic applications
• Specied with high ambient and process temperature ratings mean more
robust uses and longer service-life
• Good accuracy gage for value-sensitive applications requiring more precise
measurement and where vibration is a concern
APPLICATIONS
• Air ow indication
• Liquid level
• Draft measurement
MALE NPT
CONNECTION
[BRASS]
MALE NPT
CONNECTION [BRASS]
29/32
[23.00]
2-19/32
[66.04]
1-49/64
[44.96]
35/64
[13.97]
MALE NPT
CONNECTION
[BRASS]
35/64
[13.97]
55/64
[22.00]
2-19/32
[66.04]
SERIES LPG5
80
Single Pressure Gages, Dial
PRESSURE
DWYER INSTRUMENTS, INC. | dwyer-inst.com
SPECIFICATIONS
Service: Compatible gases and liquids.
Wetted Materials: Brass and beryllium
copper.
Housing: Drawn steel, black nish.
Lens: Polycarbonate (removable).
Accuracy: ±1.5% FS.
Pressure Limit: 100% of range scale.
Temperature Limits: Process: -40 to
160°F (-40 to 70°C); Ambient: -40 to
140°F (-40 to 60°C).
Size: 2.5˝ (63 mm).
Process Connections: 1/4˝ male NPT.
Enclosure Rating: NEMA 3 (IP54).
Weight: 7.3 oz (0.21 kg).
Our Series LPG4 2.5˝ Low Pressure Gage offers top of the line performance and
accuracy for pressure and vacuum applications up to and including 160 in w.c. The
LPG4 is constructed from a single beryllium-copper diaphragm afxed to a precision-
machined brass plate. This innovative design, together with a high-precision, milled-
teeth brass movement and nickel-silver pinion and bearing surface, provide the user
with a top of the line low pressure instrument.
FEATURES/BENEFITS
• Low pressure gage provides a selection to meet specic applications
• Specied with high ambient and process temperature ratings mean more robust
uses and longer service-life
• High accuracy gage for applications
requiring more precise measurement
is a concern
APPLICATIONS
• Air ow indication
• Liquid level
• Draft measurement
2.5˝ LOW PRESSURE GAGE
1.5% Full-Scale Accuracy in a 2.5” Gage
ø2.625
[67.7]
.550 SQUARE [14.0]
[1/4 - 18NPT]
BOTTOM CONNECTED
1.500
[38]
.850 [21.6]
SERIES LPG4
OPTIONS
Use order code: Description
NISTCAL-PG1 NIST traceable calibration certicate
MODEL CHART
Model
Range
in w.c. (kPa) Model
Range
psi (kPa)
LPG5-D8022N
LPG5-D8122N
LPG5-D8222N
LPG5-D8422N
0 to 10 (0 to 2.5)
0 to 15 (0 to 3.75)
0 to 35 (0 to 8.75)
0 to 60 (0 to 15)
LPG5-D8622N
LPG5-D8822N
LPG5-D9922N
LPG5-D0022N
0 to 100 (0 to 25)
0 to 200 (0 to 50)
0 to 5 (0 to 35)
0 to 10 (0 to 70)
Note: Change 22N to 42N for back connection option.
MODEL CHART
Model Range Model Range
LPG4-D7122N
LPG4-D7222N
LPG4-D7322N
LPG4-D7422N
LPG4-D7522N
LPG4-D7622N
LPG4-D7722N
LPG4-D7822N
LPG4-D7922N
LPG4-D8022N
LPG4-D8122N
LPG4-D8222N
-10 to 0 in w.c. (-2.5 to 0 kPa)
-15 to 0 in w.c. (-4 to 0 kPa)
-25 to 0 in w.c. (-6 to 0 kPa)
-40 to 0 in w.c. (-10 to 0 kPa)
-60 to 0 in w.c. (-15 to 0 kPa)
-80 to 0 in w.c. (-20 to 0 kPa)
-100 to 0 in w.c. (-25 to 0 kPa)
-160 to 0 in w.c. (-40 to 0 kPa)
-235 to 0 in w.c. (-60 to 0 kPa)
0 to 10 in w.c. (0 to 2.5 kPa)
0 to 15 in w.c. (0 to 3.75 kPa)
0 to 25 in w.c. (0 to 6 kPa)
LPG4-D8322N
LPG4-D8422N
LPG4-D8522N
LPG4-D8622N
LPG4-D8722N
LPG4-D8922N
LPG4-D9022N
LPG4-D9122N
LPG4-D9222N
LPG4-D9322N
LPG4-D9422N
LPG4-D9522N
0 to 40 in w.c. (0 to 10 kPa)
0 to 60 in w.c. (0 to 15 kPa)
0 to 80 in w.c. (0 to 20 kPa)
0 to 100 in w.c. (0 to 25 kPa)
0 to 160 in w.c. (0 to 40 kPa)
-4 to 0 to 6 in w.c. (-1 to 0 to 1.5 kPa)
-6 to 0 to 10 in w.c. (-1.5 to 0 to 2.5 kPa)
-8 to 0 to 16 in w.c. (-2 to 0 to 4 kPa)
-16 to 0 to 24 in w.c. (-4 to 0 to 6 kPa)
-24 to 0 to 40 in w.c. (-6 to 0 to 10 kPa)
-30 to 0 to 50 in w.c. (-7.5 to 0 to 12.5 kPa)
-40 to 0 to 60 in w.c. (-10 to 0 to 15.0 kPa)
OPTIONS
Use order code: Description
NISTCAL-PG1 NIST traceable calibration certicate
Pressure_2021.indb 80 7/15/20 8:19 AM