Instruction Manual

Series L4 Flotect
®
Float Switch
Specications - Installation and Operating Instructions
Bulletin E-73
Rugged and reliable the Series L4 Flotect
®
Float Switch operates automatically to
indicate tank level. Perfect for starting or stopping pumps, opening or closing valves,
or actuate level alarm signals. A unique magnetically actuated switching design gives
superior performance. There are no bellows, springs, or seals to fail. Instead, the free-
swinging oat attracts a magnet within the solid metal switch body, actuating a snap
switch by means of a simple lever arm. Float arm hinge design limits the arm angle to
prevent vertical hangup.
BENEFITS/FEATURES
Leak proof body machined from bar stock
Choice of oats dependent on maximum pressure and specic gravity
Weatherproof, designed to meet NEMA 4
Explosion-proof (listings included in specications)
Installs directly and easily into tank with a thredolet or ange (see application
drawings on page 4)
• Electrical assembly can be easily replaced without removing the unit from the
installation so that the process does not have to be shut down
Horizontal installation or optional top mount vertical installation
APPLICATIONS
Direct pump control for maintaining level
Automatic tank dump operations
Control levels or provide alarms in sumps, scrubber systems, hydro-pneumatic
tanks, low pressure boilers, and various waste water/sewage treatment processes
SPECIFICATIONS
Service: Liquids compatible with wetted materials.
Wetted Materials: Float and rod: 316 SS; Body: Brass or 316 SS standard; Magnet
keeper: 430 SS standard, 316 SS or nickel optional.
Temperature Limits: 4 to 275°F (-20 to 135°C) standard, MT high temperature
option 400°F (205°C) [MT option not UL, CSA, ATEX or IECEx]. ATEX, IECEx
options: Ambient temperature -4 to 163°F (-20 to 73°C); Process temperature -4 to
163°F (-20 to 73°C).
Pressure Limit: Brass body 1000 psig (69 bar), 316 SS body 2000 psig (138 bar).
Standard oat rated 100 psig (6.9 bar). For other oats see model chart on next
page.
Enclosure Rating: Weatherproof and Explosion-proof. Listed with UL and CSA for
Class I, Groups C and D; Class II, Groups E, F, and G.
ATEX
2813 II 2 G Ex db IIB T6 Gb -20°C≤Tamb≤73°C.
-20°C≤Process Temp≤73°C.
EU-Type Certicate No.: KEMA 03 ATEX 2383.
ATEX Standards: EN60079-0: 2012 + A11: 2013; EN60079-1: 2014.
IECEx Certied: For Ex db IIB T6 Gb -20°C≤Tamb≤73°C. -20°C≤Process
Temp≤73°C.
IECEx Certicate of Conformity: IECEx DEK 11.0071.
IECEx Standards: IEC 60079-0: 2011; IEC 60079-1: 2014.
Switch Type: SPDT snap switch standard, DPDT snap switch optional.
Electrical Rating: UL, FM, ATEX or IECEx models: 10A @ 125/250 VAC (V~). CSA
models: 5A @ 125/250 VAC (V~); 5A res., 3A ind. @ 30 VDC (V). MV option: 1A @
125 VAC (V~); 1A res., .5A ind. @ 30 VDC (V
). MT option: 5A @ 125/250 VAC
(V~). [MT and MV option not UL, CSA, FM, ATEX or IECEx].
Electrical Connections: UL and CSA models: 16 AWG, 6˝ (152 mm) long. ATEX or
IECEx unit: terminal block.
Conduit Connection: 3/4˝ female NPT standard or M25 x 1.5 with -BSPT option.
Process Connection: 1-1/2˝ male NPT standard, 2-1/2˝ male NPT standard
optional oats or 1-1/2˝ male BSPT.
Mounting Orientation: Horizontal installation standard, optional vertical top mount.
Weight: 4 lb 9 oz (2.07 kg).
Dead Band: 3/4˝ (19 mm) for standard oat.
Specic Gravity: 0.7 minimum with standard oat. For other oats see model
chart.
DWYER INSTRUMENTS, INC.
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A.
Phone: 219-879-8000
Fax: 219-872-9057
www.dwyer-inst.com
e-mail: info@dwyermail.com

Summary of content (16 pages)